Services


  • Design, dimensioning and analysis of power electronic and electronic circuits
  • Modeling and simulation of power electronic components and assemblies
  • Investigations in the field of electrical drives technology
  • Pre-Compliance-Tests
  • Thermal analysis

Laboratory Equipment


  • Grid simulation systems for any voltage waveform up to 30 kW three-phase (Spitzenberger & Spies EMV D 30000/PAS and EMV D 15000/PAS)
  • Motor Drive Analyzer for transient power analysis (Teledyne LeCroy MDA 8108HD, 8 channels, 12 bit, 1 GHz, 10 GS/s)
  • Bidirectional DC power supply with battery simulation up to 1000 V / 40 A / 15 kW (EA-PSB 91000-40)
  • Test benches for electrical machines up to 36 kW @ 5000 min-1 / 230 Nm @ 1500 min-1 
  • Precision power meters (ZES LMG500 und LMG450)
  • Power Scope for transient power analysis (Yokogawa PX8000)
  • 12 Bit oscilloscopes (Teledyne LeCroy Waverunner HRO 66Zi and MDA based on Waverunner 8000HD) 
  • Various dSpace rapid prototyping development systems or HIL test systems on µC and FPGA basis
  • Modular multiplex measurement system (Keithley DAQ6510 with currently 20 channels)
  • Thermal imaging camera Micro-Epsilon TIMQVGA-HD
  • Precision current transformers in various configurations
  • Various data acquisition systems from National Instruments
  • Vibration analysis system (with Ono Sokki DS-2100 and calibration system from MMF)
  • EMV-Messplatz für leitungsgebundene Netzrückwirkungen bis 30 MHz
  • Radio interference measuring receiver (Rohde und Schwarz ESPC)
  • EMC surge and burst generator (Hilo CE tester with CDN4416 coupling network)
  • Environmental simulation cabinet (CTS)
  • PCB placement machine (Fritsch PA510)
  • PCB prototyping (LPKF ProtoMat S62)
  • Prototyping reflow oven (LPKF ProtoFlow)
  • Various µC development workstations (e.g. TI C2000 real-time systems)
  • Software for model-based development (MATLAB/Simulink with corresponding toolboxes)
  • Software for numerical field calculation (ANSYS Maxwell)
  • Software for system simulation (Adapted Solutions Portunus)

and much more ...

Use of Laboratory Infrastructure


For questions regarding the use of the laboratory infrastructure, please contact:

Prof. Dr.-Ing. Christian Schumann